I. OPERATION
Place Scale on a horizontal at surface.
1. Place the scale in a vertical position with no weight
on the hook.
2. Press the ON button. Wait until zero is displayed.
3. Hang the object(s) on the weighing hook.
4. Using the [SET] key, you can switch between the
weighing units. The scale will auto-off after 60 seconds
of no use.
II. TARE WEIGHING
1. Turn on scale as described above.
2. Place the "tare item" on the hook.
3. Press [TARE] and wait until zero is displayed.
4. Add the "net-weight-item".
III. ADVANCED CALIBRATION
Calibration is NOT required before rst use. Only
calibrate if scale is not weighing properly.
1. Turn off the scale.
2. Press and hold the TARE and ON/OFF keys at the
same time.
3. Release the ON/OFF key rst, then the TARE key.
4. You will see the offset number (~1000 - 1800)
5. Press TARE and CAL will ash followed by the rst
required calibration weight.
6. Hang the rst calibration weight from the hook and
press TARE.
7. The second reuired calibration weigh will be
Comments to this Manuals